Williams Ni/Mo, 10ID August 2011

Projects

Previous Studies

Log Book Reference

Notes

Ni in situ Sulfiding

#

filename

description

Temp

Gas

EXAFS/XANES

Done

PIC

33952-27-1 Sample "II", Ni/Ni+Mo = 0.33 from South Carolina, dried only

20.9mg of 181.5mg sam/181.7mg BN in 4 barrel

Sample "II", Ni/Ni+Mo = 0.30 from South Carolina, calcined, (NiO+MoO3) loading = 15 wt%

19.5mg of 117.5mg sam/118.2 mg BN in 4 barrel

step 1

AR Ni EXAFS

step 1

11Aug_Ni11.001-009

As Received at RT in He, spot1

RT

100% He

9 EXAFS

done

step 1

11Aug_Ni12.001-009

As Received at RT in He, spot3

RT

100% He

9 EXAFS

done

step 2

ramp to 400C at 2deg/min and dwell 120 min in 9% H2S/He

step 2

purge with 9% H2S/He at 100cc/min wait 5 min then start data collection and ramp

step 2

11Aug_Ni11.010-061

Sulfidation

RT to 400C

9% H2S/He

xanes

done

step 2

11Aug_Ni12.010-060

Sulfidation

RT to 400C

9% H2S/He

xanes

done

step 3

Cool to RT

step 1

11Aug_Ni11.062-070

After sulfidation, spot1

RT

100% He

9 EXAFS

done

step 1

11Aug_Ni12.062-070

After sulfidation, spot3

RT

100% He

9 EXAFS

done

UOP/10ID.2011.08.NiMo (last edited 2011-08-24 20:04:09 by MeghanCharochak)